Dryvac Dry Screw Pump Standard Service Scope of Work

- Decontamination and removal of toxic materials and safe disposal in accordance with regional and federal regulations
- Expert evaluation and inspection
- Standard cleaning of all working surfaces
- Replacing of consumable parts such as o-rings, gaskets, plugs and shipping caps with new genuine OEM parts
- Replacing wear items such as bearings, shafts, bushings and rotors with new genuine OEM parts
- Replacing, if necessary, sight glasses, motor couplings, dirt traps, sensors, thermostatic valves, and regulators
- Reuse of cylinders, gearbox, intermediate plates, end flanges, covers, and gears, if in tolerance
- Check of motor operation
- Expert reassembly
- Testing to the same stringent standards as new pumps
- Relabeling
- Return with a 12-month OEM warranty
Oil
- A charge of appropriate LEYBONOL hydrocarbon or PFPE gear oil will be shipped inside the pump.
ATEX
- The above Scope of Work does not address ATEX-rated pumps. Contact Intlvac for additional information.
Exclusions
- B, P, and M100S series pumps are no longer supported
- Items not covered in the Standard Scope of Work include motor repair or replacement, gearbox, cylinder, intermediate plate, end flanges, covers, gears, attached accessories, and missing parts.